Differential protection of generator or alternator electrical4u. Pdf modern line current differential protection solutions. Through fault means a fault outside the zone of protection. In this research analyzes the reasons for the current reverse in. Protection functions bias differential protection 87 harmonic restraint protection over fluxing i. Designed to seamlessly consolidate functions, relion relays are smarter, more flexible and more adaptable. Provides line current faults and differential protection to power lines.
Aug 30, 2018 the differential protection is provided in the generator by using longitudinal differential relay. Sn65c1168esep dual differential drivers and receivers. Applying digital line current differential relays over. Line current differential protection free download as powerpoint presentation. Sep 08, 2016 calculation for transformer differential protection given details. As discussed in the post transformer differential protection, differential protection is supposed to operate for the internal faults or for the zone of protection it is intended for. Lightning and surge protection basics phoenix contact. Line current differential protection principlesintroduces the reader to the 87l operation principles, design challenges, and solutions. This is especially true of line current differential applications applied to. In this example we will assume that the entry and exit. A typical dc circuit for busbar differential protection scheme is given below. Differential current protection how is differential current.
Key words transformer, inrush, excitation, differential. Easy to integrate and with an extensive function library, the relion family of protection and control delivers advanced functionality and improved performance. From a design perspective, the distributed nature of the line current differential system imposes limits on the amount of data that can be exchanged between the system terminals and calls for data. Differential protection for arbitrary 3ph power transformer. The main application concern with differential protection is to make it secure from operating on false differential current. Differential protection can be used to provide protection for zones with multiple terminals and can be used to protect lines, generators, motors, transformers, and other electrical plant. Modern line current differential protection solutions sel. Pdf ct failure detection for differential protection applications. Technical guide protection criteria for medium voltage. Restricted earth fault protection restricted earth fault how it works on the hv side, the residual current of the 3 line cts is balanced against the output current of the ct in the neutral conductor. Differential current protection how is differential. Used for protecting this par are two threephase current differential protection relays one for primary differential system 87p, and another for secondary 87s. Current comparison relays with associated communication media current differential line protection current differential relaying is a method of extending the benefits of differential protection as applied to transformers, buses or generators to the protection of transmission lines.
Pdf current transformers are used widely in the power system for metering and protective relaying purposes. It is based on the fact that it is only in the case of faults internal to the zone that the differential current difference between input and output currents will be high. The papers are grouped in sections that cover the following topics. Modern line current differential protection solutions. Differential protection what goes in must come out. High impedance busbar differential protection will not work properly if the cts are not sized correctly for the connected circuit.
Numerical differential protection by gerhard ziegler. How to determine the effectiveness of generator differential. Initially this book covers the theory and fundamentals of analog and numerical differential protection. Current transformers in a differential scheme must be chosen to. Overall differentail protection for thermal power plant.
Detecting ct failure and blocking the stator differential protection is also very common practice. Abstractdifferential protection is often touted as being the protection for generator stator windings. In this type of relay, there are restraining coils. In systems where over current or distance protection systems are present, busbars will be inherently protected. When the transmission line length is too short, less than 10 miles, distance protection becomes more difficult to coordinate. Differential protection of transformer differential.
The differential protection is designed to protect power transformers or highvoltage motors. In these instances the best choice of protection is current differential protection. The differential relay works on the principle of comparison between the phase angle. Accurate power transformer modeling and proper current transformer selection lead us to improved transformer protection. Us4851950a electrical apparatus for magnetothermal and. Above currents will be the base current for each side. In electric current differential protection of busbar, if ct secondary circuits, or bus wires is open the relay may be operated to isolate the bus from live system.
Figure 1 shows a simple differential protection scheme, also known as a merzprice scheme in this simple scheme, we can assume that under normal operating conditions, the current entering into the piece of equipment under protection is equal or in the case of a transformer, proportional to its exiting current. The technical manual for this device gives instructions for its installation, commissioning, and operation. Current differential line protection setting consideration. The differential protection relay is used for the protection of the generator, transformer, feeder, large motor, busbars etc. An electrical apparatus for magnetothermal and differential protection, of the type comprising a device for sensing differential currents associated with a magnetothermal protection switch, comprises a differential current sensor connected to an input of a controlled gain signal amplifier, in turn connected to a plurality of light indicators arranged to go on progressively in. Scope this document introduces the application of the threephase differential protection in ref542plus. In this paper, we examine the degree of protection afforded by the various types of differential elements phase, negative, and zero sequence for stator winding faults. Generally differential protection is provided in the electrical power transformer rated more than 5mva. Sel387l line current differential relay schweitzer. It is applied in many variants for electrical machines, trans. In order to match these two current values, so that no relay differential current flows under healthy conditions, an interposing ct will be required to adjust the main line ct output of 3. The differential protection is provided in the generator by using longitudinal differential relay.
Paralleling cts for line current differential applications. False differential current is differential current that does not exist in the primary circuits. Protection of phase angle regulating using digital relays. Protective relay systems measure the current, voltage, or a combination of. Percentage differential protection electrical concepts. Communications and time sourcesdiscusses communications.
Transformer protection relays provide primary protection, control, and backup protection of transformers, including current differential protection. The dc offset in the primary current can cause the flux in. The outputs from the respective current transformers are thus 4. Protective relays, associated communication systems, voltage and current sensing devices. Another common form of protection for apparatus such as transformers, generators, busses and power lines is current differential. Differential protection for a generator is mainly employed for the protection of stator windings of generator against earth faults and phasetophase faults. What is the advantage of differential relay over over current. It is assumed with these schemes that a certain degree of ct saturation is possible under throughfault conditions. Differential protection is a fast and selective method of protection against shortcircuits. The relay was able to automatically compensate for the power transformer vector group connection and even to compensate for the current magnitude differences caused by onload tapchanger oltc operation. Bogdan kasztenny and normann fischer, schweitzer engineering laboratories, inc. Generally instantaneous attracted armature type relays are used for this purpose because all they have high speed operation and also they are free from being affected by any ac transient of the power circuit. The best thing with differential relay is the concept of zone which it can protect. Vid differential input voltage3 receiver 14 14 v vo output voltage driver 0.
Mar 23, 2016 differential protection setting calculations 87t pickup set above the magnetizing current and other ct inaccuracies 0. Ieee guide for application of digital line current. There are numbers of free electrons and ions present in the medium separating the two. The following are the classification of the differential protection relay. Pdf on feb 16, 2018, hank miller and others published modern line current differential protection solutions find, read and cite all the research you need on researchgate. It is based on the fact that it is only in the case of faults internal to the zone that the differential current difference between input and output currents will be high however, the differential current can sometimes be substantial even without an internal fault. Current differential protection of transmission line. This scheme is free from blind spots, it can have a high degree of sensitivity. This is especially true of line current differential applications applied to breakerandahalf and ringbus configurations. The main source of false differential current is ct saturation. This brochure provides you with an overview of lightning and surge protection for electrical systems.
Busbar protection busbar differential protection scheme. When the system is in normal operating condition, the magnitude of currents is equal on the secondary windings of the current transformers. Sn65c1168esep dual differential drivers and receivers with. Bus bar protection schemes,simple current differential scheme,need for bus bar protection,requirement of bus bar protection,recommendations for providing bus b slideshare uses cookies to improve functionality and performance, and to. Abstract digital current differential protection has the advantages of application simplicity, operation speed, and high sensitivity. The analysis and solution of current differential protection. Differential protection is not supposed to operate for a through fault. Simple backup protectionchoose the sel387l as a simple solution for discrete backup protection. Lightning and surge protection basics we dont just want to support you with excellent solutions, but also to be on hand with help and advice.
Pdf advanced line current differential protection with reduced. The faults occur in the transformer inside the insulating oil can be detected by buchholz relay. The objective of protection is to remove only the affected portion of plant and nothing else. For generator differential protection, one set of current transformers ct are located on generator neutral side, whereas second set of ct is located on generator phase side.
The differential protection of transformer has many advantages over other schemes of protection. This includes basic information about engineering and electronics topics. Line current differential protection relay electrical. Protection relays differential relays 2 using biased relay. L to limit current through relay to differential protection in power transformer. Apr 28, 2018 as discussed in the post transformer differential protection, differential protection is supposed to operate for the internal faults or for the zone of protection it is intended for. It should be noted that over current protection will only be applied to relatively simple distribution systems, or as a backup protection, which gives a considerable.
Current differential protection is based o n kirchhoffs current law and the change of differential current can ef fectively reflect whether the busbar is faulty or not, it is a widely used protection. A differential relay is defined as the relay that operates when the phase difference of two or more identical electrical quantities exceeds a predetermined amount. Traditionally, current differential protection communication channels are either direct fiber optic cable or multiplexed. Percentage restrained differential, percentage of what. Differential protection can selectively protect a specified zone i. The principles of differential protection you must. Biased differential protection is set to protect the common primary series unit winding and the primary exciting unit winding. Differential protection of generator or alternator. Aug 31, 2018 in current differential protection of busbar, if ct secondary circuits, or bus wires is open the relay may be operated to isolate the bus from live system. Applying digital line current differential relays over pilot wires 73 1. Bus protection, automatic reclosing, 292 by backup relays, 275, 291 circuitbreaker bypsasing, 292 combined power transformer and bus, 287 current differential with overcurrent relays, 278 current differential with overvoltage relays, 288 current differential with percentage relays, 284 directional comparison, 277 fault bus, 275 grounding.
Degree of earth fault protection is very much improved by the application of unit differential or restricted earth fault systems. Differential protection and distance protection selectivity. Biased differential protection, restricted earth fault. Digital current differential relays power line carrier figure 1. Differential protection is a unittype protection for a specified zone or piece of equipment. To understand why and how windings fail, we need to know. Easy to integrate and with an extensive function library, the relion family of protection and control delivers advanced functionality and. Transformer protection relay current differential protection. This is designed to response to the differential current in the term of its fractional relation to the current flowing through the protected section.
We calculated that the voltage across the nonsaturated ct, when another ct saturates, is 83. Principles of differential relaying my protection guide. Abstractline current differential protection creates challenges for relay design and application. Principles of differential relaying current balance high impedance also known as unbiased differential protection only one actuating relay quantity current required for operation. Abstractparalleling current transformers cts is a common practice in differential or line protection applications where the number of cts exceeds the number of relay current inputs. Backup considerations for line current differential protection. Transformer differential protection linkedin slideshare. Circuit breakers provide a manual means of energizing and deenergizing a circuit. Abstractline current differential 87l protection relies on communications for the exchange of current values and, if. At this time, the differential protection of sc lines may fail to operate due to insufficient sensitivity. This type of protection works on the basic theory of kirchhoffs current law, which states that the sum of the currents entering and exiting a node will equal zero. Differential current protection of transformer using arduino. Coordinate with another local relay, such as an sel551 overcurrentreclosing relay, to provide breaker failure, autoreclose, overcurrent, and ground fault protection functions in addition to current differential protection. If overall differential protection is set to 20% the function will pickup when 20% of the base secondary current is injected as a symmetrical threephase current from each respective side see section 4.
1653 1607 836 794 1665 123 308 1165 348 335 151 1581 1180 567 1405 167 1634 60 1317 1261 480 638 1085 1027 808 272 1378 1657 981 822 757 1385 266 316 616 1096 1459 338 1082 1381 586 240 1044 30